Ventilation ducts in multi-storey and commercial buildings under normal conditions (for environments with chemical vapors / high risk of corrosion SC50 is recommended)
PRODUCT FEATURES
Seals leaks and holes in the ducts. Which reduces energy consumption and extends service life
Protects the duct from rust and corrosion by acting as a protective layer. Our solution can also be used in ducts where there is already rust/corrosion
Fire retardant. Almost impossible to ignite and self-extinguishing. Tested cf. the requirements in DS / En 1361-1 2013 and DS428 (fire technical measures in ventilation ducts)
Dust-repellent
Resistant to impact, high elasticity and self-healing for minor injuries
Waterproof
High adhesion and easy to work with
RECOMMENDED FILM THICKNESS
Film thickness:
Wet film ± 355 my
Dry film: ± 200 my
FLASH POINT:
Non-flammable, fire retardant
PH RESISTANCE:
N/A
VOC
5g/l
TOUCH DRY AT
At 20° - 2 hours
Ventilation ducts exposed to conditions that increase the risk of corrosion. Suitable for environments with chemical vapors in the air. Recommended for use on ships / maritime, as well as production facilities
PRODUCT FEATURES
Seals leaks and holes in the ducts. Which reduces energy consumption and extends service life
Protects the duct from rust and corrosion by acting as a protective layer. Our solution can also be used in ducts where there is already rust/corrosion
Excellent chemical resistance / resistance to chemical vapors. The coating has been tested in acidic, alkaline and chlorine-containing environments with pH values from 3-12, where no signs of degradation of the coating materials are seen. Tested according to DS / EN ISO 2812-3, 2012
Fire retardant. Almost impossible to ignite and self-extinguishing. Tested cf. the requirements in DS / En 1361-1 2013 and DS428 (fire technical measures in ventilation ducts)
Resistant to impact, high elasticity and self-healing for minor injuries
High adhesion and easy to work with
Dust-repellent
RECOMMENDED FILM THICKNESS
Film thickness:
Wet film ± 355 my
Dry film: ± 200 my
FLASH POINT:
Non-flammable, fire retardant
PH RESISTANCE:
Good resistance to chemical vapors with pH values from 3 to 12. However, different acids, bases etc. can have different effects on the coatings. Therefore, if one is to be sure, then the coating must be tested specifically against the media to which they will be exposed in the individual application.
VOC
5g/l
TOUCH DRY AT
At 20° - 2 hours
Drains and downspouts
PRODUCT FEATURES
High adhesion
Easy to work with
Rust protected in water pipes
Can be used as an adhesive primer (diluted with 25% water)
Waterproof
High elasticity
Impact resistant
RECOMMENDED FILM THICKNESS
Film thickness:
Wet film ± 635 my
Dry film: ± 365 my
FLASH POINT:
Non-flammable, melts at high temperatures
PH RESISTANCE:
Corrosion class 4 – at 800g/m2 (=365 my Dry film)
VOC
5g/l
TOUCH DRY AT
At 20° - 2 hours